Advanced Data Formatting 14 - 23
Setup Field(s)
Table 14-1    
Setup Field(s) Definitions
Parameter
Description
Page
Move Cursor
Move Cursor To a Character
Scan 
, then any printable ASCII 
character from the 
. This moves the 
cursor to the position after the matching character. If the 
character is not there, the rule fails and ADF tries the next rule.
Move Cursor to Start of Data
Scan this bar code to move cursor to the beginning of the data.
Move Cursor Past a Character 
This action moves the cursor past all sequential occurrences of 
a selected character. For example, if the selected character is 
‘A’, then the cursor moves past ‘A’, ‘AA’, ‘AAA’, etc. Scan 
, then select a character from the 
. If the character is not there, the 
cursor does not move (i.e., has no effect).
Skip Ahead “N” Characters
Scan one of these bar codes to select the number of positions 
ahead to move the cursor.
Skip Back “N” Characters
Scan one of these bar codes to select the number of positions 
back to move the cursor.
Send Preset Value
Send Values 1 through 6 by scanning the appropriate bar 
code. Set these values using the prefix/suffix values in 
.
Value 1 = Scan Suffix
Value 2 = Scan Prefix
Values 3-6 are not applicable