Konica Minolta 250 用户手册

下载
页码 468
Specifying management settings
9
200/250/350
9-29
Spe
c
if
y
ing
 ma
nag
eme
n
t s
e
tti
ng
s
Chap
ter
 9
9.8
Specifying software switch settings (machine func-
tions)
By using the software switch settings, the mode, bit, and HEX values of each 
function of the machine can be changed from the factory settings to meet 
your specific needs.
2
Reminder 
Do not change any modes or bits other than those described in this man-
ual.
2
Note 
When “Enhance Security” is set to “ON”, the software switch settings 
cannot be changed.
Software switch settings
Examples of settings in bit selection (binary numbers) and HEX selection 
(hexadecimal numbers) are shown below.
Item
Description
Mode Selection
Parameters to be specified are represented by a three-digit 
number. Type in the value using the keypad. 
Bit Selection
A mode status is expressed with an eight-digit number. By 
specifying a binary number (1 or 0) for each of the bits 0 through 
7, a setting can be specified for each parameter.
HEX Selection
The settings of each mode are expressed using hexadecimal 
numbers (combinations of 0-9 and A-F). The bit selection 
“00110000” equals the HEX selection “30”. 
Specify mode settings either with bit or hexadecimal selections.
Decimal 
number
Bit Selection (binary number)
HEX Selection (hexadecimal 
number)
0 0000 
0000
00
1 0000 
0001
01
2
0000 0010
02
3
0000 0011
03
4
0000 0100
04
5
0000 0101
05
6
0000 0110
06
7
0000 0111
07