Philips V30 用户手册

下载
页码 109
To access factory mode
1. Turn off monitor (don't turn off PC)
2. Press '"
" and "
" simultaneously on the front control
panel,then press "
",wait till the OSD menu with characters
V30 107T5 V0.48 20021218 (below OSD menu)" come on the
screen of monitor.
3. If OSD menu disappears on the screen of monitor, press "
"
again (anytime), then the OSD menu comes on the screen again.
4. Using "
" : to select OSD menu.
5. Using "
" : to increase or decrease the setting.
6. Using "
" to access/confirm the selection.
7. After alignment of factory mode, turn off monitor (if you do not turn
off monitor, the OSD menu is always at the factory mode), then
turn on monitor again (at this moment, the OSD menu goes back
to user mode).
To leave factory mode
13
Lock/Unlock, Factory Mode, Burn In, Service Mode
9
Go to cover page
OSD Lock
Switch on OSD lock feature:
Switch off OSD lock feature:
OSD lock is a feature which disables the OSD controls. It can be used
when the monitor is set up for demonstration purposes or when
adjustment of the OSD is not desirable.
Press and hold the
button continuously for 15 seconds.
Release the button when the message
"CONTROL MENU IS LOCKED" appears.
Press and hold the
button continuously for 15 seconds or until the
message window "CONTROL MENU IS LOCKED" disappears, and
"MAIN CONTROLS" appears.
To access BURN IN mode
Reconnect the video cable, then return to normal image.
First of all, monitor displays an image.
1. Disconnect the video cable (interface cable).
2. Turn off monitor
3. Press '"
" and "
" simultaneously on the front control
panel,then the BURN IN mode comes on the screen of monitor
as below.
50 seconds around
5 seconds around
repeatly
4.
SERVICE MODE (Indication-Factory mode)
MODEL SELECT
02060
V30 107T5 V0.48 20021218
------------------------>
02060: stands for
1. using 10 hours already.
2. turn on/off 10 times.
3. using several hours
+ turn on/off monitor.
Default setting of MODEL SELECT (Do not change it.)
MODEL SELECT
107T5
107B5
RESERVE
RESERVE
RESERVE
SWDDC
MODEL SELECT
V30 107T5 V0.48 20021218
Factory
Mode
Indicator
LF 3
107T5