Philips 107B7 用户手册

下载
页码 80
17” CDT Color Monitor                                                            107B7        
 
7
2. Precautions and notices                                                     
 
2-1.Safety precautions 
 
1.  Observe all caution and safety related notes located inside the display cabinet. 
2.  Operation of the display with the cover removed, may cause a serious shock hazard from the display power 
supply. Work on the display should not be attempted by anyone who is not thoroughly familiar with 
precautions necessary when working on high voltage equipment. 
3.  Do not install, remove or handle the picture tube in any manner unless shatter-proof goggles are worn. 
People who are not so equipped should be kept away while handling picture tube. Keep picture tube away 
from the body while handling. 
4.  The picture tube is constructed to limit X-RAY radiation to 0.5 mR/HR. For continued protection, use the 
designated replacement tube only, and adjust the voltages so that the designated maximum rating at the 
anode will not be exceeded. 
5.  Symbol“   “ means safety relative parts. The use of substitute replacement parts which do not have the 
same characteristics as specified in the parts list may create shock, fire or explode etc. 
6. Symbol“    ”  means X-ray relative parts. Before replacing any of these components please read the parts 
list    in this manual carefully to avoid creating higher anode voltage or x-ray. Especially for sealed controls, 
such as VR902  and FBT screen VR etc, which were sealed by the manufacturer once their optimum 
position has been set, please don’t dismantle them as your likes, otherwise you will break or damage the 
component. If you need replace the parts with sealed control, please adjust the relative VR to make sure the 
B+ voltage about 53.5.0V and well seal it with A+B glue or equivalent, which you can not move away with 
one screw driver 
7.  Before returning a serviced display to the customer, a thorough safety test must be performed to verify that 
the display is safe to operate without danger or shock. Always perform an AC leakage current check on the 
exposed metallic parts of the cabinet, such as screw heads.   
Test method for current leakage is described as follow. 
(a)  Plug the AC line cord directly into rated AC outlet (do not use a line isolation transformer during this 
check). 
(b)  Use an AC voltmeter having 5000 ohms per volt or with more sensitivity in the following manner: 
Connect a 1500 ohms 10 Watt resistor, paralleled by a 0.15UF, AC type capacitor between a known 
good earth ground (water pipe, conduit, etc.) and the exposed metallic parts simultaneously. Measure 
the AC voltage across the combination of 1500 ohms resistor and 0.15UF capacitor. 
(c)  Reverse the AC plug at the AC outlet and repeat AC voltage measurements for each exposed metallic 
part. 
(d)  Voltage measured must not exceed 0.5 volts RMS. This corresponds to 0.35 milliamp AC. Any value 
exceeding this limit constitutes a potential shock hazard and must be corrected immediately.