Theory of Device Operation 
 
(3) FIR circuit 
This circuit is 10-tap sampled analog transversal filter circuit that equalizes the 
head read signal to the Modified Extended Partial Response (MEEPR) waveform. 
(4)  A/D converter circuit  
This circuit changes Sampled Read Data Pulse from the FIR circuit into Digital 
Read Data. 
(5)  Viterbi detection circuit 
The sample hold waveform output from the flash digitizer circuit is sent to the 
Viterbi detection circuit.  The Viterbi detection circuit demodulates data according 
to the survivor path sequence. 
4.6.4  Digital PLL circuit 
The drive uses constant density recording to increase total capacity.  This is 
different from the conventional method of recording data with a fixed data transfer 
rate at all data area.  In the constant density recording method, data area is divided 
into zones by radius and the data transfer rate is set so that the recording density of 
the inner cylinder of each zone is nearly constant.  The drive divides data area into 
30 zones to set the data transfer rate. 
The MPU set the data transfer rate setup data (SD/SC) to the RDC block that 
includes the Digital PLL circuit to change the data transfer rate. 