Operations 
 
6.1.4  Response to diagnostic command 
When the master device receives an EXECUTE DEVICE DIAGNOSTIC 
command and the slave device is present, the master device checks the PDIAG- 
signal for up to 6 seconds to see if the slave device has completed the self-
diagnosis successfully. 
The master device does not check the DASP- signal. 
After the slave device receives the EXECUTE DEVICE DIAGNOSTIC command, 
it shall report the result of the self-diagnostics to the master device as described 
below: 
PDIAG- signal:  negated within 1 ms and asserted within 5 seconds 
The asserted PDIAG-signal is negated 5 seconds after it is asserted if the command 
is not received. If the command is received, the PDIAG-signal is negated 
according to timing at which the command is received. 
When the IDD is set to a slave device, the IDD asserts the DASP- signal when 
negating the PDIAG- signal. 
 
Max. 6 sec.
Max. 5 sec.
Max. 1 ms.
If the slave device is preset, PDIAG- signal is checked for
up to6 seconds.
DASP-
PDIAG-
BSY bit
X'1F7' Reg.
Write
Status Reg.
BSY bit
Slave device
Master device
 
 
Figure 6.4  Response to diagnostic command 
 
6-6 
C141-E258