Fujitsu MHW2080BJ 用户手册

下载
页码 320
 
5.3  Host Commands 
5.3  Host Commands 
The host system issues a command to the device by writing necessary parameters
in related fields in the shadow block registers and writing a command code i
Command field of the shadow block registe
 
n the 
rs. 
 
tatus). 
 
reset. 
 
ata 
ck 
d. 
The device can accept the command when the BSY bit is 0 (the device is not in 
the busy s
The host system can halt the uncompleted command execution only at execution
of COMRESET or software 
When the BSY bit is 1 or the DRQ bit is 1 (the device is requesting the PIO d
transfer) and the host system writes to the command field of the shadow blo
register, the correct device operation is not guarantee
5.3.1  Command code and parameters 
Table 5.5 lists the supported commands, command code and the related fields to 
be written necessary parameters at command execution. 
Table 5.5  Command code and parameters (1/3) 
COMMAND CODE (Bit) 
PARAMETER USED 
COMMAND NAME 
7 6 5 4 3 2 1 0 FR 
SC 
SN 
CY
DH
RECALIBRATE 
0 0 0 1 X X X X N N N N D 
READ 
SECTOR(S) 
0 0 1 0 0 0 0 R N Y Y Y Y 
WRITE 
SECTOR(S) 
0 0 1 1 0 0 0 R N Y Y Y Y 
WRITE 
VERIFY 
0 0 1 1 1 1 0 0 N Y Y Y Y 
READ 
VERIFY 
SECTOR(S) 
0 1 0 0 0 0 0 R N Y Y Y Y 
SEEK 
0 1 1 1 X X X X N N Y Y Y 
EXECUTE 
DEVICE 
DIAGNOSTIC 1 0 0 1 0 0 0 0 N N N N N 
INITIALIZE 
DEVICE 
PARAMETERS
1 0 0 1 0 0 0 1 N Y N N Y 
DOWNLOAD 
MICROCODE 
1 0 0 1 0 0 1 0 Y Y Y N D 
STANDBY IMMEDIATE 
1
0
0
1
0
1
0
0
N N N N D 
IDLE IMMEDIATE 
1
0
0
1
0
1
0
1
Y N Y Y D 
UNLOAD IMMEDIATE 
1
0
0
1
0
1
0
1
Y N Y Y D 
STANDBY 
1
0
0
1
0
1
1
0
N Y N N D 
C141-E259 
5-27