Fujitsu MHY2060BH 用户手册

下载
页码 322
Interface 
 
5-4 
C141-E262 
5.1.2  Signal interface regulation 
5.1.2.1  Out of band signaling 
During OOB signaling transmissions, the differential and common mode levels of 
the signal lines shall comply with the same electrical specifications as for in-band 
data transmission, specified as follows. 
COMRESET/COMINIT
106.7 ns
320 ns
COMWAKE
106.7 ns
106.7 ns