Fujitsu MBB2147RC 用户手册

下载
页码 98
 
3.1  Data Space 
 
 
Each sector on the track consists of the following fields: 
 
(1) 
Gaps (G1, G2, G3) 
 
No pattern is written on the gap field. 
 
(2) PLO 
Sync 
 
In this field, pattern X'00' is written. 
 
(3) 
Sync Mark (SM1, SM2) 
 
In this field, special pattern is written.  This special pattern indicates the beginning of the data field. 
(4) 
Data field (DATA1-DATA4) 
 
User data is stored in the data field of the sector.  The length of the data field is equal to that of the 
logical data block which is specified with a parameter in the MODE SELECT command.  Any 
multiple of 4 between 512 and 528 bytes can be specified as the length. 
(5) BCRC 
 
It is a 4-byte error detection code.  Single burst errors with lengths of up to 32 bits for each logical 
block can be detected. 
 
(6) ECC 
 
This is the 400 bits code that allows detection and correction of errors in the data field, which is 
capable of correcting the single burst error up to 200 bits max. on the fly. 
 
(7) PAD 
 
A specified length of x‘00’ pattern is written in this field.  This field includes the variation by rotation 
and circuit delay till reading/writing. 
 
C141-E257 
33