6.1  Device Response to the Reset
 
C141-E202-01EN 6-5 
6.1.3  Response to software reset 
The master device does not check the DASP- signal for a software reset.  If a 
slave device is present, the master device checks the PDIAG- signal for up to 15 
seconds to see if the slave device has completed the self-diagnosis successfully. 
After the slave device receives the software reset, the slave device shall report its 
presence and the result of the self-diagnostics to the master device as described 
below: 
PDIAG- signal:  negated within 1 ms and asserted within 30 seconds 
The asserted PDIAG-signal is negated 30 seconds after it is asserted if the 
command is not received. 
When the IDD is set to a slave device, the IDD asserts the DASP- signal when 
negating the PDIAG- signal. 
 
 
Max. 31 sec.
Max. 30 sec.
Max. 1 ms.
If the slave device is preset, PDIAG- is checked for
up to 31 seconds.
DASP-
PDIAG-
BSY bit
X"00"
X'3F6' Reg.
X"0C"
or X"04"
Status Reg.
BSY bit
Slave device
Master device
 
 
Figure 6.3  Response to software reset