5.2  Logical Interface
 
C141-E217 
5-7 
5.2.1  I/O registers 
Communication between the host system and the device is done through input-
output (I/O) registers of the device. 
These I/O registers can be selected by the coded signals, CS0-, CS1-, and DA0 to 
DA2 from the host system. Table 5.2 shows the coding address and the function 
of I/O registers. 
Table 5.2  I/O registers 
     
I/O 
registers 
 
     
Read 
operation 
Write 
operation  
Command block registers 
L H L L L 
Data 
Data 
X’1F0’ 
L H L L H 
Error 
Register 
Features 
X’1F1’ 
L H L H L 
Sector 
Count 
Sector 
Count X’1F2’ 
L H L H H 
Sector 
Number 
Sector 
Number 
X’1F3’ 
Cylinder Low 
Cylinder Low 
X’1F4’ 
L H H L H 
Cylinder 
High 
Cylinder 
High 
X’1F5’ 
L H H H L 
Device/Head 
Device/Head X’1F6’ 
L H H H H 
Status 
Command 
X’1F7’ 
L L X X X 
(Invalid) 
(Invalid) 
— 
Control block registers 
H L H H L 
Alternate 
Status 
Device 
Control 
X’3F6’ 
H L H H H 
— 
— 
X’3F7’ 
 
Notes: 
1. 
The Data register for read or write operation can be accessed by 16 bit data 
bus (DATA0 to DATA15). 
2. 
The registers for read or write operation other than the Data registers can be 
accessed by 8 bit data bus (DATA0 to DATA7). 
3. 
When reading the Drive Address register, bit 7 is high-impedance state. 
4. 
H indicates signal level High and L indicates signal level Low. 
 
There are two methods for specifying the LBA mode.  One method is to 
specify the LBA mode with 28-bit address information, and the other is to 
specify it with 48-bit address information (command of EXT system).  If 
the LBA mode is specified with 28-bit address information, the 
Device/Head, Cylinder High, Cylinder Low, Sector Number registers 
Host I/O
address 
DA0 
DA1 
DA2 
CS1– 
CS0–