Fujitsu MAW3300fc 用户手册

下载
页码 112
 
7.2  Sense Data Analysis 
C141-E235 
7-3 
7.2 
Sense Data Analysis 
7.2.1 
Error information indicated with sense data 
 
Subsection 7.2.2 onwards explain troubleshooting using sense data.  For details of the following 
sense data, refer to Chapter 5 “Sense Data Error Recovery Methods” of the Fibre Channel Interface 
Specifications. 
 
Table 7.1 lists the definition of sense data.  For details of sense data, refer to the Fibre Channel 
Interface Specifications. 
Table 7.1 
Definition of sense data 
Sense data 
Sense 
key 
Additional 
sense code 
Additional 
sense code 
qualifier 
Definition 
00 
00 
00 
Operation was normal. 
0C 
03 
A write to a disk terminated abnormally. 
32 
01 
Failed to update the defect list due to a disk medium write error, 
etc. 
 
40 
xx 
An error occurred in power-on self-diagnosis. 
 
C4 
xx 
A drive error occurred. 

1x 
1x 
xx 
xx 
A disk read error occurred. 
A disk read error occurred. 
1D 
00 
Data discrepancy found by VERIFY command byte check. 
2x 
xx 
A SCSI error, such as an invalid operation code, occurred. 
4 or B 
44 
xx 
A hardware error occurred inside the HDD. 
47 
00 
A CRC error occurred in the fibre channel loop. 
 
49 
00 
An unmounted or inappropriate message was received. 
 
4E 
00 
An overlap command was issued.