Baldor E100 用户手册

下载
页码 138
www.supportme.net
5-14 Input / Output
MN1942
5.4 Ethernet interface
The Ethernet interface provides TCP/IP and ETHERNET Powerlink (EPL) networking capabilities.
5.4.1 TCP/IP
Transmission Control Protocol / Internet Protocol (TCP/IP) is a common set of protocols used to
transfer information between devices over a network, including the internet. TCP enables two
devices to establish a connection, and guarantees the delivery of packets (datagrams) of
information in the correct order. IP specifies the format of the individual packets (which includes
the destination address of the receiving device) but has no influence on whether the packet is
delivered correctly.
TCP/IP allows the MicroFlex e100 to support standard Ethernet communication with a host PC
running Mint WorkBench. The connection uses Baldor’s high level ICM (Immediate Command
Mode) protocol to allow Mint commands, Mint programs and even firmware to be sent to the
controller over the Ethernet network.
When operating in standard Ethernet mode, TCP/IP cannot be used to communicate with a
controller on a daisy-chained network. This is due to cumulative timing errors caused by each
controller’s internal hub. It is necessary to connect the host PC to the controller either directly or
via a single hub, as shown in Figure 34:
Host PC
External hub
MicroFlex e100 drives
Figure 34 - Connecting to drives using TCP/IP in standard Ethernet mode
When operating in EPL mode, in conjunction with an EPL compatible router, the host PC can use
TCP/IP to communicate with controllers on a daisy-chained network. In this situation, the router
will use TCP/IP only within EPL’s asynchronous time slots. See the Mint help file for further
details.
Host PC
ETHERNET Powerlink
compatible router
NextMove e100
Master Node
MicroFlex e100 drives
Figure 35 - Connecting to daisy-chained drives using TCP/IP and EPL mode