Motorola ATCA-717 用户手册

下载
页码 156
Requirements
Installation
PENT/ATCA−717
37
Requirements
In order to meet the environmental requirements, the blade has to be tested in the system
in which it is to be installed.
a
Before you power up the blade, calculate the power needed according to your
combination of blade upgrades and accessories.
Environmental Requirements
The environmental conditions must be tested and proven in the shelf configuration used.
The conditions refer to the surrounding of the blade within the user environment.
aaa
Note:
a
S The environmental requirements of the blade may be further limited down due to
installed accessories, such as hard disks or PMC modules, with more restrictive
environmental requirements
S Operating temperatures refer to the temperature of the air circulating around the
blade and not to the actual component temperature.
S Blade damage
Blade surface
High humidity and condensation on the blade surface causes short circuits.
Do not operate the blade outside the specified environmental limits. Make sure the
blade is completely dry and there is no moisture on any surface before applying
power. Do not operate the blade below 0
°C.
S Blade Overheating and Blade Damage
Operating the blade without forced air cooling may lead to blade overheating and
thus blade damage.
When operating the blade, make sure that forced air cooling is available in the
shelf.
Table 4:
 Environmental Requirements
Requirement
Operating
Non−Operating
Temperature
0
°C to +55°C (may be
further limited by
installed
accessories)
aaaa
–40
°C to +85°C (may be
further limited by
installed accessories)
aa
Temp. Change
a
 +/– 0.5
°C/min
a
 +/– 1
°C/min