AMCC 9500S 用户手册

下载
页码 103
Enclosure Object Commands
www.3ware.com 
87
Enclosure Object Commands
Enclosure object commands provide information and perform actions related 
to a specific enclosure, such as /e0 and its elements, such as /e0/slot0
Enclosure object elements include slot, fan, and temperature sensor elements.
These commands are supported on the 9550SX, 9590SE, and 9650SE 
controllers, when an appropriate enclosure is used. The enclosure must use an 
integrated AMCC/3ware CCU (chassis control unit). (Check the 3ware web 
site for a list of chassis vendors that support enclosure services, as they 
become available.) If you purchased an enclosure directly from a third-party 
vendor, the appropriate EPCT (Enclosure Port Configuration Table) must 
have been downloaded to the controller in order to take advantage of these 
commands. 
                                      
Syntax
/ex show                         (9550SX, 9590SE, 9650SE only)
/ex show attribute [attribute ...] where attributes are:
controllers|slots|fans|temp
/ex show all                     (9550SX, 9590SE, 9650SE only)
/ex/slotx show                   (9550SX, 9590SE, 9650SE only)
/ex/slotx show identify         (9550SX, 9590SE, 9650SE only)
/ex/slotx set identify=on|off  (9550SX, 9590SE, 9650SE only)
/ex/fanx show                    (9550SX, 9590SE, 9650SE only)
/ex/tempx show                   (9550SX, 9590SE, 9650SE only)
/ex show
This command shows summary information on the specified enclosure /ex
This report consists of four parts; the Enclosure summary listing the present 
elements, a Fan summary section listing of all present fans, a Temperature 
Sensor summary section listing of all present temperature sensors and a Slot 
summary section listing of slots and associated information for the specified 
enclosure. 
Note.
 Not all enclosure features may be available on enclosures that use an 
integrated AMCC/3ware CCU.