Installation Instructions
2-15
2
IP Installation on the MVME162LX
Up to two IPs may be installed on the 700/800-series MVME162LX. 
Install the IPs on the board as follows:
1. Each IP has two 50-pin connectors that plug into two 
corresponding 50-pin connectors on the MVME162LX: J5/J6, 
J7/J8. See Figure 2-1 for the MVME162LX connector 
locations.
РOrient the IP(s) so that the tapered connector shells mate 
properly. Plug IP_a into connectors J5 and J6; plug IP_b 
into J7 and J8. If a double-sized IP is used, plug IP_ab into 
J5, J6, J7, and J8.
2. Two additional 50-pin connectors (J3 and J4) are provided 
behind the MVME162LX front panel for external cabling 
connections to the IP modules. There is a one-to-one 
correspondence between the signals on the cabling 
connectors and the signals on the associated IP connectors 
(i.e., J4 has the same IP_a signals as J5; J3 has the same IP_b 
signals as J7).
РConnect user-supplied 50-pin cables to J3 and J4 as 
needed. Because of the varying requirements for each 
different kind of IP, Motorola does not supply these 
cables.
РBring the IP cables out the narrow slot in the MVME162LX 
front panel and attach them to the appropriate external 
equipment, depending on the nature of the particular 
IP(s).