Diagnostic Facilities
3-25
3
The address appears as: 
Diagnostic Facilities
The 162Bug package includes a set of hardware diagnostics for 
testing and troubleshooting the MVME162LX. To use the 
diagnostics, switch directories to the diagnostic directory. If you are 
in the debugger directory, you can switch to the diagnostic 
directory with the debugger command Switch Directories (
SD
). The 
diagnostic prompt
162-Diag>
appears. Refer to the Debugging Package for Motorola 68K CISC CPUs 
User's Manual
 for complete descriptions of the diagnostic routines 
available and instructions on how to invoke them. Note that some 
diagnostics depend on restart defaults that are set up only in a 
particular restart mode. The documentation for such diagnostics 
includes restart information. 
Manufacturing Test  Process
During the manufacturing process for MVME162LXs, the 
manufacturing test parameters and testing state flags are stored in 
NVRAM. These strings are installed during the manufacturing 
process and result in the product performing manufacturing tests. 
None of these tests harm the product or system into which a board 
is installed. Entering an ASCII break on the console port from a 
terminal terminates these tests. 
The two state flags that start the test processes are: 
FLASH EMPTY$00122984 
and 
Burnin test$00000000 
GPCSR0 GPCSR1