National Instruments PXI-8462 用户手册

下载
页码 60
Appendix B
Cabling Requirements for PXI-8460 Low-Speed CAN
B-6
ni.com
Philips also recommends an individual device RTH and RTL termination of
500
Ω to 16 kΩ. The PXI-8460 board ships with mounted RTH and RTL
values of 510
Ω ±5% per port. The PXI-8460 kit also includes a pair of
15 k
Ω ±5% resistors for each port. After determining the termination of
your existing network or device, you can use the following formula to
indicate which value should be placed on your PXI-8460 board in order to
produce the proper overall RTH and RTL termination of 100 to 500
Ω upon
connection of the board:
*R
RTH overall
should be between 100 and 500
Ω
**R
RTH of low-speed CAN interface
= 510
Ω ±5% (mounted) or 15 kΩ ±5% (in kit)
R
RTH
R
RTL
As the formula indicates, the 510
Ω ±5% shipped on your board will work
with properly terminated networks having a total RTH and RTL termination
of 125 to 500
Ω, or individual devices having an RTH and RTL termination
of 500
Ω to 16 kΩ. For communication with a network having an overall
RTH and RTL termination of 100 to 125
Ω, you will need to replace the
510
Ω resistors with the 15 kΩ resistors in the kit. Please refer to the next
section, Replacing the Termination Resistors.
R
RTH overall*
1
1
R
RTH of low-speed CAN interface**
-----------------------------------------------------------------
1
R