National Instruments 3.21E+04 用户手册

下载
页码 181
Chapter 4     Signal Connections
AT-MIO/AI E Series User Manual
4-56
 National Instruments Corporation
Mode 1 Output Timing
The following are the timing specifications for an output transfer in 
Mode 1:
Figure 4-39.  Mode 1 Output Timing
Name
Description
Minimum
Maximum
T1
WR* = 0 to INTR = 0
250
T2
WR* = 1 to Output
200
T3
WR* = 1 to OBF* = 0
150
T4
ACK* = 0 to OBF* = 1
150
T5
ACK* Pulse Width
100
T6
ACK* = 1 to INTR = 1
150
All timing values are in nanoseconds.
WR*
OBF*
INTR
ACK*
DATA
T1
T2
T3
T4
T5
T6