National Instruments 3.21E+04 用户手册

下载
页码 181
Chapter 1     Introduction
AT-MIO/AI E Series User Manual
1-6
 National Instruments Corporation
Custom Cabling 
National Instruments offers cables and accessories for you to prototype 
your application or to use if you frequently change board 
interconnections.
If you want to develop your own cable, however, the following 
guidelines may be useful:
For the analog input signals, shielded twisted-pair wires for each 
analog input pair yield the best results, assuming that you use 
differential inputs.  Tie the shield for each signal pair to the ground 
reference at the source.
You should route the analog lines separately from the digital lines.
When using a cable shield, use separate shields for the analog and 
digital halves of the cable.  Failure to do so results in noise coupling 
into the analog signals from transient digital signals.
The following list gives recommended part numbers for connectors that 
mate to the I/O connector on your AT E Series board.
Mating connectors and a backshell kit for making custom 68-pin 
cables are available from National Instruments (part number 
776832-01)
AT-MIO-16E-1, AT-MIO-16E-2, AT-MIO-16E-10, 
AT-MIO-16XE-10, AT-AI-16XE-10, and the AT-MIO-16XE-50
Honda 68-position, solder cup, female connector (part number 
PCS-E68FS)
Honda backshell (part number PCS-E68LKPA)
AT-MIO-64E-3 and AT-MIO-16DE-10
AMP 100-position IDC male connector (part number 1-750913-9)
AMP backshell, .50 max O.D. cable (part number 749081-1)
AMP backshell, .55 max O.D. cable, (part number 749854-1)