Warning: Exceeding the maximum input voltage ratings, which are listed in 
Tables 4-1 through 4-4, can damage the AT E Series board and the PC. 
National Instruments is 
NOT
 liable for any damages resulting from such 
signal connections.
Figure 4-11 shows signal connections for three typical digital I/O 
applications. 
Figure 4-11.  Digital I/O Connections
Figure 4-11 shows DIO<0..3> configured for digital input and 
DIO<4..7> configured for digital output.  Digital input applications 
include receiving TTL signals and sensing external device states such 
as the state of the switch shown in the figure.  Digital output 
applications include sending TTL signals and driving external devices 
such as the LED shown in the figure.
LED
+5 V
TTL Signal
+5 V
DIO<4..7>
DIO<0..3>
DGND
Switch
I/O Connector
AT E Series Board