Omega Engineering OME-A8111 用户手册

下载
页码 34
2.7  A/D Conversion 
 
This section explains how to perform A/D conversions. The A/D conversion 
can be performed by software trigger by pacer trigger. At the end of the 
A/D conversion, it is possible to transfer data by polling and interrupt 
before using the A/D conversion function; users should notice the following 
issues: 
 
z
  A/D data register, BASE+4/BASE+5, stores the A/D conversion data  (sec. 2.4.2) 
z
  A/D gain control register, BASE+9, select gain   (sec. 2.4.6) 
(sec. 2.4.7) 
z
  A/D multiplex control register, BASE+A, select analog input   
z
  A/D mode control register, BASE+B, select trigger type and transfer 
type  (sec. 2.4.8) 
z
  A/D software trigger control register, BASE+C    (sec. 2.4.9) 
 
 
The block diagram is given below: 
 
Base+C 
OME-A-8111 
Base+B 
Base+A 
Base+9 
Trigger 
Logic 
CPU 
Transfer 
Logic 
 
Memory 
 
Buffer 
12 bits 
A/D 
Gain 
Control 
7 to 0 
Multi- 
plexer 
CN1 
 
 
 
 
 
 
 
 
 
 
 
 
OME-A-8111 Hardware Manual (ver.1.1, Jul/2003)                                      21