Cypress CY7C1527AV18 用户手册
CY7C1516AV18, CY7C1527AV18
CY7C1518AV18, CY7C1520AV18
CY7C1518AV18, CY7C1520AV18
Document Number: 001-06982 Rev. *D
Page 24 of 30
Output Times
t
CO
t
CHQV
C/C Clock Rise (or K/K in single
clock mode) to Data Valid
clock mode) to Data Valid
–
0.45
–
0.45
–
0.45
–
0.45
–
0.50
ns
t
DOH
t
CHQX
Data Output Hold after Output C/C
Clock Rise (Active to Active)
Clock Rise (Active to Active)
–0.45
–
–0.45
–
–0.45
–
–0.45
–
–0.50
–
ns
t
CCQO
t
CHCQV
C/C Clock Rise to Echo Clock Valid
–
0.45
–
0.45
–
0.45
–
0.45
–
0.50
ns
t
CQOH
t
CHCQX
Echo Clock Hold after C/C Clock
Rise
Rise
–0.45
–
–0.45
–
–0.45
–
–0.45
–
–0.50
–
ns
t
CQD
t
CQHQV
Echo Clock High to Data Valid
–
0.27
–
0.27
–
0.30
–
0.35
–
0.40
ns
t
CQDOH
t
CQHQX
Echo Clock High to Data Invalid
–0.27
–
–0.27
–
–0.30
–
–0.35
–
–0.40
–
ns
t
CQH
t
CQHCQL
Output Clock (CQ/CQ) HIGH
1.24
–
1.35
–
1.55
–
1.95
–
2.45
–
ns
t
CQHCQH
t
CQHCQH
CQ Clock Rise to CQ Clock Rise
(rising edge to rising edge)
(rising edge to rising edge)
1.24
–
1.35
–
1.55
–
1.95
–
2.45
–
ns
t
CHZ
t
CHQZ
Clock (C/C) Rise to High-Z
(Active to High-Z)
(Active to High-Z)
–
0.45
–
0.45
–
0.45
–
0.45
–
0.50
ns
t
CLZ
t
CHQX1
Clock (C/C) Rise to Low-Z
–0.45
–
–0.45
–
–0.45
–
–0.45
–
–0.50
–
ns
DLL Timing
t
KC Var
t
KC Var
Clock Phase Jitter
–
0.20
–
0.20
–
0.20
–
0.20
–
0.20
ns
t
KC lock
t
KC lock
DLL Lock Time (K, C)
1024
–
1024
–
1024
–
1024
–
1024
–
Cycles
t
KC Reset
t
KC Reset
K Static to DLL Reset
30
–
30
–
30
–
30
–
30
–
ns
Switching Characteristics
(continued)
Over the Operating Range
[20, 21]
Cypress
Parameter
Consortium
Parameter
Description
300 MHz
278 MHz
250 MHz
200 MHz
167 MHz
Unit
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
Notes
24. These parameters are extrapolated from the input timing parameters (t
KHKH
- 250 ps, where 250 ps is the internal jitter. An input jitter of 200 ps (t
KC Var
) is already
included in the t
KHKH
). These parameters are only guaranteed by design and are not tested in production.
25. t
CHZ
, t
CLZ
. Transition is measured
±100 mV from steady-state voltage.
26. At any voltage and temperature t
CHZ
is less than t
CLZ
and t
CHZ
less than t
CO
.