Cypress CY7C1316CV18 用户手册

下载
页码 29
CY7C1316CV18, CY7C1916CV18
CY7C1318CV18, CY7C1320CV18
Document Number: 001-07160 Rev. *E
Page 23 of 29
Switching Characteristics
Over the Operating Range 
Cypress 
Parameter
Consortium 
Parameter
Description
267 MHz
250 MHz
200 MHz
167 MHz
Unit
Min
Max
Min
Max
Min
Max
Min
Max
t
POWER
V
DD
(Typical) to the First Access 
1
1
1
1
ms
t
CYC
t
KHKH
K Clock and C Clock Cycle Time
3.75
8.4
4.0
8.4
5.0
8.4
6.0
8.4
ns
t
KH
t
KHKL
Input Clock (K/K and C/C) HIGH
1.5
1.6
2.0
2.4
ns
t
KL
t
KLKH
Input Clock (K/K and C/C) LOW
1.5
1.6
2.0
2.4
ns
t
KHKH
t
KHKH
K Clock Rise to K Clock Rise and C to C Rise 
(rising edge to rising edge)
1.68
1.8
2.2
2.7
ns
t
KHCH
t
KHCH
K/K Clock Rise t o C/C Clock Rise 
(rising edge to rising edge)
0.00 1.68 0.00
1.8
0.00
2.2
0.00
2.7
ns
Setup Times
t
SA
t
AVKH 
Address Setup to K Clock Rise
0.3
0.5
0.6
0.7
ns
t
SC
t
IVKH
Control Setup to K Clock Rise (LD, R/W)
0.3
0.5
0.6
0.7
ns
t
SCDDR
t
IVKH
Double Data Rate Control Setup to Clock (K/K) 
Rise (BWS
0
, BWS
1
, BWS
2
, BWS
3
)
0.3
0.35
0.4
0.5
ns
t
SD 
t
DVKH
D
[X:0]
 Setup to Clock (K and K) Rise
0.3
0.35
0.4
0.5
ns
Hold Times
t
HA
t
KHAX
Address Hold after K Clock Rise
0.3
0.5
0.6
0.7
ns
t
HC
t
KHIX
Control Hold after K Clock Rise (LD, R/W)
0.3
0.5
0.6
0.7
ns
t
HCDDR
t
KHIX
Double Data Rate Control Hold after Clock (K/K) 
Rise (BWS
0
, BWS
1
, BWS
2
, BWS
3
)
0.3
0.35
0.4
0.5
ns
t
HD
t
KHDX
D
[X:0] 
Hold after Clock (K/K) Rise
0.3
0.35
0.4
0.5
ns
Notes
21. When a part with a maximum frequency above 167 MHz is operating at a lower clock frequency, it requires the input timings of the frequency range in which it is being 
operated and outputs data with the output timings of that frequency range.
22. This part has an internal voltage regulator; t
POWER
 is the time that the power is supplied above V
DD 
minimum initially before a read or write operation can be initiated.
23. For DQ2 data signal on CY7C1916CV18 device, t
SD