Chapter 4
Troubleshooting Procedures
4-5
If the hard drive responds correctly to
probe-scsi
, the message identified in
is displayed. If the drives respond and a message is displayed, the
system SCSI controller has successfully probed the devices. This is an indication that
the motherboard is operating correctly. If one drive does not respond to the SCSI
controller probe but the other does, replace the unresponsive drive. If one hard drive
is configured with the system and the
probe-scsi
test fails to show the device in
the message, replace the drive. If the problem is still evident after replacing the hard
drive, replace the SCSI drive bay (see Section 8.3, “Hard Drive Bay With SCSI
Assembly” on page 8-7) 
If replacing both the hard drive and the SCSI drive bay does
not correct the problem, replace the motherboard.
4.4
Power Supply Test
The section describes how to test the power supply.
and
identify
power supply connector J2901.
and
identify power supply
connector J2902.
and
identify power supply connector J2903.
1. Power off the system.
2. Remove the side access cover.
3. Slide the power supply from the chassis enough to expose connectors J2901
through J2903.
4. Power on the system.
5. Using a digital voltage meter (DVM), check the power supply output voltages as
follows:
Note –
Power supply connectors J2901 through J2903 must remain connected to the
motherboard.
a. With the negative probe of the DVM placed on a connector ground (Gnd) pin,
position the positive probe on each power pin.
b. Verify voltage and signal availability as listed in
and
6. If any power pin signal is not present with the power supply active and properly
connected to the motherboard, replace the power supply.