Magnetek TM7310rev01 用户手册
Quattro DC Interconnections
16
GND
L(1) L(2) L(3)
* Note 1
* Note 1
H(X) H(1)
Provided for
the Primary
side of the
230V control
power
transformer
To Quattro Drive
F1
F2
Internal Control
Power
2
3
TB1
Motor Field Control
SWout (+)
DCout (-)
A24
Motor Shunt Field
(F1)
(F2)
* Note 1
* Note 1
4
3
2 1
TB1K1 K1 TB1 ME TB1 TB1
Located on A9
Safety Chain
* Note 1
Safety Chain
DBR
1-4
1-4
DBR
5-8
5-8
ME
ME
ME
(4) (3)
(5) (6)
(2) (1)
(A1)
(A2)
* Note 1
Encoder to
A6TB1
A6TB1
Notes:
1. * indicates components
1. * indicates components
not supplied by Magnetek
Hoist Motor
K1
Part of A9
ME
ME
ME
(21) (22)
(13) (14)
(43) (44)
Motor Contactor Auxiliaries
230VAC hi
230VAC lo
Control Power
Figure 2: Quattro DC Power Connections