Samsung 3.5" hard disk drives 用户手册

下载
页码 115
DISK DRIVE OPERATION 
 
SpinPoint V40 Product Manual
 
89
 
6.7 Timing 
 
The minimum cycle time supported by the device in PIO mode 3, 4 and Multiword DMA mode 1, 2 
respectively, shall always be greater than, or equal to the minimum cycle time defined by the associated 
mode. For example, a device supporting PIO mode 4 timing shall not report a value less than 120ns, the 
minimum cycle time defined for PIO mode 4 timings.  
 
 
6.7.1 Register 
transfers 
 
Figure 6-1 defines the relationships between the interface signals for register transfers.  Peripherals reporting 
support for PIO mode 3 or 4 shall power up in a PIO mode 0, 1, or 2. 
 
For PIO modes 3 and above, the minimum value of t
0
 is specified by word 68 in the IDENTIFY DEVICE 
parameter list.  Table 6-16 defines the minimum value that shall be placed in word 68. 
 
IORDY will be supported when PIO modes 3 or 4 are the current mode of operation.  
 
NOTE 
 Some devices implementing the PACKET Command feature set prior to this 
standard power up in PIO mode 3 and enable IORDY as the default.