Promise Technology M310p 用户手册

下载
页码 262
Chapter 8: Troubleshooting
207
Figure 4. Fan LED on a VTrak M310p/M210p cooling unit
Under normal conditions, the power supply, battery, and fan LEDs should display 
green.
To check a component’s installation, follow the same procedure as replacing the 
component, except that you reinstall the original component rather than a new 
one. In most cases, this action fixes a bad connection and allows VTrak to detect 
the component. If this action does not correct the problem, replace the unit. See 
page 167 for instructions. 
Figure 5. A VTrak M310p/M210p controller
Under normal conditions, the Controller Status LED (marked with 
 icon) is 
green and the Dirty Cache LED (marked with 
) icon is dark. See the table, 
below.
LEDs
State
Dark
Green
Amber
Red
Power supply
Not detected
OK
Fan too slow
Failed
Battery
Not detected
OK
Low capacity
Fan
Not detected
OK
Fan too slow
Failed
Fan LED
Battery LED
Mgmt
CONSOLE
Status LED
Dirty Cache LED