DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Routine Maintenance Procedures 
Page 5-10
Replacing Components (Release 5vs or Later) 
5
8. Reseat the port circuit packs one at a time following the same steps 
outlined above for control circuit packs.
9. If none of the control or port circuit packs appears to be defective, replace 
the power unit. 
10. When the system reboot has completed, return the EMER XFER 
(Emergency Transfer) switch to AUTO. This restores the system to the 
normal operating mode.
Replacing Components (Release 5vs 
or Later)
Components within the Release 5vs can be replaced while the unit is attached to 
the wall. Also, if the wires and cables at the back of the cabinet are neatly 
bundled, these wires and cables need not be disconnected.
 an
 provide views of the power supply sub-assembly. 
 provides a view of the fan sub-assembly. The sections following the 
figures discuss how to disassemble the unit and then replace the power supply 
or fans within the unit.
!
CAUTION:
When replacing either the power supply or the fans within a Release 5vs 
unit that is already attached to the wall, you should disconnect the entire fan 
panel from the unit. Otherwise, if the fan panel is left to dangle, the cable 
assemblies leading out from the fans (which are connected to the fan 
panel) and into the backplane might become damaged or disconnected 
from the backplane.