Maintenance Object Repair Procedures
Page 10-129
ASAI-EPT
10
ASAI-EPT
The maintenance strategy for this endpoint MO is built on maintenance facilities
offered in the Lucent ISDN-BRI protocol and in the ASAI adjuncts. Currently there
are no facilities in the protocol that provide for maintenance of set data features.
offered in the Lucent ISDN-BRI protocol and in the ASAI adjuncts. Currently there
are no facilities in the protocol that provide for maintenance of set data features.
The TN800 is a PC-based platform that allows interaction of multiple applications
with DEFINITY at any time. DEFINITY Release 5 software (Native mode) supports
emulation of three types of port MOs on this board. The type of ports to be
emulated is defined by the applications running on the TN800.
with DEFINITY at any time. DEFINITY Release 5 software (Native mode) supports
emulation of three types of port MOs on this board. The type of ports to be
emulated is defined by the applications running on the TN800.
NOTE:
If the TN800 is emulating BRI, the software/firmware supports a maximum
of 12 ports, but only 8 of the 12 ports can be administered at any one time.
If the TN800 is emulating BRI, the software/firmware supports a maximum
of 12 ports, but only 8 of the 12 ports can be administered at any one time.
Error Log Entries and Test to Clear Values
1.
The alarm level for ASAI adjuncts is administered using the
set options
command. The
alarm level can be set independently for off-board and on-board alarms to WARNING,
MINOR, or MAJOR for all ASAI adjuncts in the system.
MINOR, or MAJOR for all ASAI adjuncts in the system.
MO Name (in
Alarm Log)
Alarm Level
Initial Command to Run
Full Name of MO
ASAI-EPT
MAJOR
1
test station extension
ASAI-Adjunct
Table 10-43.
ASAI-EPT Error Log Entries
Error
Type
Type
Aux
Data
Associated Test
Alarm
Level
ASAI-EPT
On/ Off
Board
Test to Clear Value
0
1
0
Any
Any
Any
test ASAI-ADJ
2 (a)
2-102
None
257 (b)
Any
BRI Layer 3 Query
MAJ/WNG
2
OFF
test station ext r 2
test data-module ext r 2
test data-module ext r 2
351 (c)
0
none
WARNING
OFF
busyout and release
station
station
513 (d)
0
None
769 (e)
0
None
MAJOR
OFF
2561 (f)
0
None
2562-
2566 (g)
2566 (g)
0
None
Continued on next page