Maintenance Object Repair Procedures
Page 10-174
BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI ISDN-BRI Port)
10
Electronic Power Feed Restoral Test (#620)
This test attempts to restore the Electronic Power Feed (EPF) on an ISDN-BRI
port twice. In this test, the processor requests that the EPF be turned on for a
given port. An attempt is made to turn on the power unit to the station or adjunct.
port twice. In this test, the processor requests that the EPF be turned on for a
given port. An attempt is made to turn on the power unit to the station or adjunct.
2012
ABORT
Internal System Error.
2100
ABORT
Could not allocate the necessary resources to run this
test.
test.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
2103
ABORT
The system could not make the conference connection
for the test.
for the test.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
1, 2
FAIL
As stated previously, this test runs a TDM Loop Around
Test on each B-channel. This indicates that the loop
around failed on one of the channels. Error Code 1
indicates that the TDM Loop Around Test failed on B1.
Error Code 2 indicates that the TDM Loop Around Test
failed on B2.
Test on each B-channel. This indicates that the loop
around failed on one of the channels. Error Code 1
indicates that the TDM Loop Around Test failed on B1.
Error Code 2 indicates that the TDM Loop Around Test
failed on B2.
7, 8
FAIL
As stated previously, this test runs a Conference Circuit
Test on each B-channel. A failure here indicates that one
of these conference tests failed; Error Code 7 means
that the test failed on B1; Error Code 8 means that the
test failed on B2.
Test on each B-channel. A failure here indicates that one
of these conference tests failed; Error Code 7 means
that the test failed on B1; Error Code 8 means that the
test failed on B2.
1. If the test fails repeatedly, attempt to reset the circuit
pack if the other ports on the circuit pack are not in
use. Reset the circuit pack by issuing the
use. Reset the circuit pack by issuing the
busyout
board PCSS
and the
reset board PCSS
commands.
2. If the test fails again, replace the circuit pack.
PASS
The BRI Port Local TDM Loop Around Test has passed.
Table 10-56.
TEST #619 BRI Port Local TDM Loop Around —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page