Lucent Technologies R5SI 用户手册
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-245
CARD-MEM (Memory Card)
10
5. Once the alarm is resolved, enter the
save translation
command to store
the current system translations to the memory card.
6. If applicable, enter the
save announcements
command to store the
current announcements to the memory card.
Error Log Entries and Test to Clear Values
1.
Run the Short Test sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
appropriate test description and follow the recommended procedures.
Table 10-74.
Mrmory Card Error Log Entries
Error
Type
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
0
Any
Any
Any
test card-mem
1(a)
Memory Card Insertion
Test (#695)
Test (#695)
MINOR
OFF
test card-mem
257(b)
Memory Card Format and
Read Test (#696)
Read Test (#696)
MINOR
OFF
test card-mem
513(c)
Any
Memory Card Match and
Read Test (#697)
Read Test (#697)
WARNING
OFF
test card-mem
769(d)
Memory Card
Write-Protected Test
(#698)
Write-Protected Test
(#698)
WARNING
OFF
test card-mem
1025(e)
104
105
106
107
108
105
106
107
108
Memory Card Dir.
Recovery Test (#699)
Recovery Test (#699)
MINOR
OFF
test card-mem
1281(f)
Any
Memory Card Translation
Data Integrity Test (#694)
Data Integrity Test (#694)
MINOR
OFF
test card-mem long
1537(g)
104
105
106
107
108
105
106
107
108
Memory Card
Erase/Write/Read Test
(#693)
Erase/Write/Read Test
(#693)
MINOR
OFF
test card-mem long
3329(h)
any
None
MINOR/
MAJOR
MAJOR
OFF
3841(i)
Any
Save Translation
MINOR
OFF
save translation
3843(j)
Any
Save Translation
MINOR
OFF
save translation
Continued on next page