Maintenance Object Repair Procedures 
Page 10-252
CARD-MEM (Memory Card) 
10
Memory Card Translation Data Integrity Test 
(#694)
This test, which is nondestructive, verifies the integrity of the translation file stored 
in the memory card by reading (without any PREC updates) the translation file 
from the memory card and by then performing a checksum error checking. The 
calculated checksum value is compared with the recorded checksum value in 
the translation file. If these two values are different, this indicates that the 
translation file is corrupted.
2117
ABORT
No translation file has been saved onto the memory card.
1. Enter the 
save translation
 command, and verify that the translations are 
saved onto the memory card successfully.
2. Retry the command at 1-minute intervals a maximum of 5 times.
104
FAIL
Directories on the memory card are corrupted and cannot be recovered.
105
FAIL
"0" cannot be written into memory before an erase operation.
106
FAIL
Memory card cannot be erased.
107
FAIL
Data cannot be written onto a memory card after an erasure.
1. Replace the memory card and re-run the test.
108
FAIL
12 volt power supply for the Memory Card Erase/Write/Read Test can’t be 
turned on. The 12 volt power supply on TN777B NETCON circuit pack may 
be defective.
1. Re-enter the 
test card-mem
 command, and verify the result of Test 701 
for the 12 Volt Power Supply.
2. If Test 701 fails, follow the Standard Repair Procedure to replace the 
TN777B NETCON circuit pack with a new TN777B circuit pack.
3. Retry the command a 1-minute intervals a maximum of 5 times.
Table 10-75.
TEST #693 Memory Card Erase/Write/Read Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page