DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-289
CARR-POW (Carrier Port Power Unit) for DC-Powered Systems 
10
Figure 10-23.
645B Port Carrier Power Unit for DC-Powered Systems
Port Carrier Power Unit Replacement Procedures
The procedures for replacing a 644A or 645B carrier DC power unit are given 
below.
If the port carrier power unit to be replaced is in a control carrier of a PPN 
system, refer to the "Removing Power" and "Restoring Power" sections in Chapter 
5, "Routine Maintenance Procedures" before replacing the port carrier power 
unit. To replace the port carrier power unit, follow the procedure below:
1. If this is a 645B power unit, set the power switch to OFF.
2. Unplug the power cord.
3. Move the locking slide on the power unit to the extreme left position, and 
unlatch the locking lever.
4. Remove the power unit from the carrier.
STATUS
LOCKING
LEVER
LOCKING
SLIDE
POWER
CORD
OUTLET
ON
OFF
LEDS
RED
AMBER