Maintenance Object Repair Procedures 
Page 10-301
CLSFY-PT (Call Classifier Port) 
10
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order presented in the following tables when 
inspecting errors in the system. By clearing error codes associated with the 
Tone 
Detection Verification Test
, for example, you may also clear errors generated 
from other tests in the testing sequence.
Tone Detection Verification Test (#42)
This test checks out each port in both the touch-tone receiver mode and in the 
R2-MFC tone detection/generation mode. During the first half of the test, the 
touch-tone receiver mode is tested. In the second half of the test, each port is put 
into the R2-MFC mode. During this portion of the test, each port’s ability to 
accurately detect and generate all forward and backward MFC tones is verified.
1.
D = Destructive; ND = Nondestructive
Order of Investigation
Short Test 
Sequence
Long 
Test 
Sequence
D/ND
1
Tone Detection Verification Test (#42)
X
X
ND
Tone Detection Audit/Update Test (#43)
X
X
ND
Table 10-86.
TEST #42 Tone Detection Verification Test 
Error 
Code
Test 
Result
Description/ Recommendation
none
ABORT
The system was not able to allocate all the resources 
needed for this test OR there was an Internal System 
Error.
1
ABORT
The system could not allocate all the resources needed 
to test the tones.
1001
ABORT
The system was unable to put the Call Classifier port in 
the appropriate mode to test it.
Continued on next page