Maintenance Object Repair Procedures
Page 10-314
CO-DS1 (DS1 CO Trunk)
10
Conference Circuit Test (#7)
One or more Network Processing Elements (NPEs) reside on each circuit pack
with a TDM Bus interface. The NPE controls port connectivity and gain, and
provides conferencing functions on a per-port basis. The Conference Circuit Test
verifies that the NPE channel for the port being tested can correctly perform the
conferencing function. The NPE is instructed to listen to several different tones
with a TDM Bus interface. The NPE controls port connectivity and gain, and
provides conferencing functions on a per-port basis. The Conference Circuit Test
verifies that the NPE channel for the port being tested can correctly perform the
conferencing function. The NPE is instructed to listen to several different tones
0
NO
BOARD
BOARD
The test could not relate the internal ID to the port (no
board). This could be due to incorrect translations, no
board is inserted, an incorrect board is inserted, an
insane board is inserted, or the board is hyperactive
(see note below).
board). This could be due to incorrect translations, no
board is inserted, an incorrect board is inserted, an
insane board is inserted, or the board is hyperactive
(see note below).
1. Check to ensure that the board translations are
correct. Use the
list config
command, and resolve
any problems that are found.
2. If the board was found to be correctly inserted in
step 1, issue the
busyout board
command.
3. Issue the
reset board
command.
4. Issue the
release busy board
command.
5. Issue the
test board long
command. This should
re-establish the linkage between the internal ID and
the port. If this is not the case, dispatch to check to
ensure that there is a valid board inserted.
the port. If this is not the case, dispatch to check to
ensure that there is a valid board inserted.
NOTE:
Hyperactivity causes some special problems with
the sequence suggested above. If the ports are
translated after issuing the
the sequence suggested above. If the ports are
translated after issuing the
list config
command
but the ’Vintage’ field reports that there is no board
(when there really is a board), then the
(when there really is a board), then the
busyout
board
and the
release busy board
commands
will not work (even though the
reset board
command will work). The software will put the
hyperactive board back in service after the
hyperactivityclears.
hyperactive board back in service after the
hyperactivityclears.
Table 10-88.
TEST #6 NPE Crosstalk Test —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page