DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-336
CO-TRK (CO Trunk) 
10
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order they are presented in the table below when 
inspecting errors in the system. By clearing error codes associated with the 
NPE 
Crosstalk Test,
 for example, you may also clear errors generated from other tests 
in the testing sequence.
For example, you may also clear errors generated from other tests in the testing 
sequence.
Notes
:
a. A demand test of Diagnostic Test (#3) always returns a PASS indication for 
CO-TRK/CO-BD [TN747B] version 8 or greater. However, any errors 
produced as a result of this test are logged and produce no alarms.
If errors logged by Test #3 are the only complaints against this trunk, then 
the system technician person should check if MFT/Range Extenders are 
being used. If extenders are present, then there is a good chance that 
there is excessive loop current, which causes Test #3 to log errors.
However, all else being normal, these errors should not affect the 
customer.
b. Refer to TIE-TRK (Tie Trunk) Maintenance documentation for a description 
of this test.
c. ATMS test are not part of either sequence. They are run either on demand 
with the 
test analog-testcall
 command or via the ATMS schedule.
Dial Tone Test (#0)
This test attempts to seize a port and checks for the return of a dial tone.
1.
D = Destructive; ND = Nondestructive
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
NPE Crosstalk Test (#6)
X
ND
Dial Tone Test (#0)
X
ND
CO Demand Diagnostic Test (#3) (a)
X
X
ND
Loop Around and Conference Test (#33)
X
ND
Audit Update Test (#36)
Analog Transmission Test (#844-848) (b)
X
(c)
X
(c)
ND