Routine Maintenance Procedures
Page 5-34
Software Upgrade
5
NOTE:
A password must have from 4 to 11 alphanumeric characters
including at least 1 alphabetic character and 1 numeric character. A
login name must have from 3 to 6 alphanumeric characters.
including at least 1 alphabetic character and 1 numeric character. A
login name must have from 3 to 6 alphanumeric characters.
11. Since an R1V3.0 G3-MA cannot notify users about expiring passwords,
disable password aging for any login name used with an R1V3.0 G3-MA.
Restart DEFINITY LAN Gateway System
1. Log onto the DEFINITY LAN Gateway.
2. When the main menu appears, select
Maintenance
.
3. Select
Reset System
from the
Maintenance
menu.
4. Select
Restart System
from the
Reset System
menu.
Save Upgraded Translations onto New
Translation Card
Translation Card
1. Enter
status system 1
, and press
Enter
to verify that the system is in the
“active/standby” mode.
NOTE:
At this point, all telephones should be working properly.
2. Insert the new Release 5.4 translation card. Verify the write switch is down.
3. The original translation card can be reformatted and reused. Enter
format
card-mem announcements
and press
Enter
. This formats the original
translation card into Release 5.4 format (even if no announcement circuit
packs are installed).
packs are installed).
4. Enter
save translation
, and press
Enter
. This instructs the system to write
all translation information from memory onto both translation cards.
5. If the system is equipped with a TN750/B Announcement circuit pack and
announcements were saved above, enter
restore announcements
, and
press
Enter
. Once the administered recorded announcements are
restored, enter
save announcements
[from PCSS] and press
Enter.
Where
P is the port network number (1 for PPN, and 2-4 for EPN), C is the carrier
designation (A, B, C, or D), and SS is the number of the slot in which the
circuit pack resides (01 to 21).
designation (A, B, C, or D), and SS is the number of the slot in which the
circuit pack resides (01 to 21).
NOTE:
If multiple TN750/B circuit packs are present, you
must
specify the
slot location for the save announcements command. If there is only
one announcement circuit pack, the system defaults to the proper
location.
one announcement circuit pack, the system defaults to the proper
location.