Lucent Technologies R5SI 用户手册
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-378
DATA-BD (Network Control Circuit Pack)
10
Error Log Entries and Test to Clear Values
Notes:
a. This error indicates the DATA-BD portion of the Network Control circuit
pack stopped functioning. Since the Network Control circuit pack cannot
be reset via the
be reset via the
reset board PCSS
command, the Data Channel Reset
Test (#107) in the Long Test Sequence for the DATA-CHLs and
DATA-CON must be used to reset it as follows:
DATA-CON must be used to reset it as follows:
1. Issue the
list data
command to determine if one, or more, Network
Control Data Channels (DATA-CHLs) is administered.
NOTE:
A Network Control Data Channel (DATA-CHL) is identified by
a "type" value of "netcon."
a "type" value of "netcon."
2. If a Network Control Data Channel (DATA-CHL) is not administered,
use the
add data-module [<ext> | next]
command to administer a
DATA-CHL.
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
appropriate test description and follow the recommended procedures.
Table 10-103.
Network Control Circuit Pack Error Log Entries
Error
Type
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
0
Any
Any
Any
test data-module
<ext> sh r 1
<ext> sh r 1
1 (a)
0
Data Channel Reset
Test (#107)
Test (#107)
MINOR
ON
test data-module
<ext> l
<ext> l
23 (b)
0
None
WARNING
OFF
257
Any
Control Channel Test
(#52)
(#52)
MINOR
ON
test network-control
[a | b] sh r 20
[a | b] sh r 20
257 (c)
0
None
513 (d)
Any
None
769 (e)
4358
None
1025 (f)
4363
NPE Audit Test (#50)
test network-control
[a | b] sh
[a | b] sh
1538 (g)
Data Channel Reset
Test (#107)
Test (#107)
MINOR
ON
test data-module
<ext> l
<ext> l
3840 (h)
Any
None
3841(i)
Any
None
3999(j)
Any
None