DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-386
DATA-CHL (Network Control Data Channel) 
10
Status of Network Control Data Channels
In order to perform maintenance testing on the Network Control DATA-CHLs, the 
DATA-CHLs cannot be busy with one of the functions described previously. A 
series of system technician commands can be used to determine if the 
DATA-CHLs are busy and, if so, to determine the function for which they are 
being used. This series of system technician commands is described below and 
should be done before testing the DATA-CHLs.
Issue the 
list data-module
 command to determine the extensions for the 
administered Network Control Data Channels (DATA-CHLs).
NOTE:
A Network Control Data Channel (DATA-CHL) is identified by a "type" value 
of "netcon."
For each Network Control Data Channel (DATA-CHL) on the Active SPE, 
determine if the DATA-CHL is busy by issuing the 
status data-module <ext>
 
command using the DATA-CHL’s extension. If the DATA-CHL is busy, the 
Service State field in the resulting form will be in service/active. However, the 
form does not indicate the reason the DATA-CHL is busy. This must be 
determined using other system technician commands.
Use the procedures below to determine whether busy Network Control Data 
Channels (DATA-CHLs) are being used for CDR, Journal Printer, or PMS Links. If 
a DATA-CHL is busy with one of these links then, in order to test the DATA-CHL, 
the link must be busied out using 
busyout smdr-link
busyout journal-printer 
wakeup-log
busyout journal-printer pms-log
, or 
busyout pms-link
 
command, respectively. Do not issue any of these busyout commands unless 
instructed to do so while investigating Error Codes according to the "System 
Technician-Demanded Tests: Descriptions and Error Codes" subsection. If one 
of these links must be busied out to perform maintenance testing, restore the link 
to service according to PRI-CDR/SEC-CDR (PRI-CDR Link), 
PMS-PRNT/JNL-PRNT (PMS Printer Link), and PMS-LINK Maintenance 
documentation, respectively.
If a DATA-CHL is busy but is not being used for one of these links, then it is being 
used for a secondary administration terminal connection or for maintenance 
testing. If it is being used for a secondary administration terminal connection, 
then in order to test the DATA-CHL that the connection is using, the DATA-CHL 
must be busied out using the 
busyout data-module <ext>
 command.
NOTE:
The 
busyout data-module <ext>
 command causes the connection over 
the associated DATA-CHL to be dropped. Do not issue this command 
unless instructed to do so.