Maintenance Object Repair Procedures 
Page 10-402
DATA-CHL (Network Control Data Channel) 
10
Data Channel Crosstalk Test (#110)
This test verifies the integrity of the entire DATA-CHL, that is, the software, dual 
port RAM, and hardware that composes it. However, unlike the Remote 
Maintenance Loop Around Test (#109), this test only involves the single 
DATA-CHL that is the target of the test. A loop around connection is established 
over the TDM Bus from the DATA-CHL back to itself. Data is looped over the 
connection in each direction, that is, the DATA-CHL is tested as both a sender of 
data and a receiver of data. The test checks that the data received by the 
DATA-CHL is the same as the data that was sent by the DATA-CHL.
Because it establishes a loop around connection from the Network Control 
DATA-CHL back to itself across the TDM Bus, this test does more than just verify 
the integrity of the target DATA-CHL. It also verifies the integrity of the 
DATA-CON (by establishing the connection) and of the TDM Bus and 
Tone-Clock circuit pack (by sending and receiving data).
If this test aborts or fails, it is impossible to determine from this test alone whether 
the target DATA-CHL is defective or if the problem lies with the DATA-CON, TDM 
Bus, or Tone-Clock circuit pack. The results of running Tests #107, #108, and 
#111 on the DATA-CHL can be used to determine whether the target DATA-CHL 
is defective.
Finally, recall from the description of that DATA-CHLs 1 and 2 share a common 
DPR and TDM Bus interface hardware and DATA-CHLs 3 and 4 share a common 
DPR and TDM Bus interface hardware. Thus, if this test finds that DATA-CHL 1 is 
defective, then DATA-CHL 2 is likely to be defective and vice versa. Similarly, if 
this test finds that DATA-CHL 3 is defective, then DATA-CHL 4 is likely to be 
defective and vice versa.
NOTE:
If an Error Code is encountered that recommends that an CDR Link, System 
Printer Link, PMS Log Printer, Wakeup-Log Printer Link, and/or PMS Link be 
busied out, restore each busied-out link to service according to the 
PRI-CDR/SEC-CDR (PRI-CDR Link), SYS-PRNT, or PMS-LINK Maintenance 
documentation, respectively, before concluding work on the problem.
PASS
The target DATA-CHL, DATA-CON, TN777 Network Control circuit pack, 
TDM Bus (TDM-BUS), and Tone-Clock circuit pack (TONE-BD, TONE-PT, 
TDM-CLK) are functioning. Connections can be established over the 
DATA-CHLs.
Table 10-110.
TEST #109 Data Channel Remote Maintenance Loop Around Test  — 
Continued