Maintenance Object Repair Procedures 
Page 10-412
DATA-CON (Network Control Driver) 
10
DATA-CON (Network Control Driver)
The TN777B Network Control circuit pack contains the following objects: the 
SW-CTL (Switch Control), four DATA-CHLs (Data Channels), the DATA-CON 
(Network Control Driver), and the generic hardware that interfaces with the TDM 
Bus (DATA-BD). The DATA-CON (Network Control Driver) is the subject of this 
section. The DATA-CHLs (Network Control Channels) are also described.
Together the four DATA-CHLs and the DATA-CON provide a data 
communications interface that allows DTE equipment connected to port circuit 
packs to communicate with software applications running on the system. The 
DATA-CON represents the interface to the control channel of the TDM Bus. Each 
DATA-CHL represents a dial-up/dial-out asynchronous communication port that 
interfaces to the TDM Bus. The DATA-CON supports the signaling required to 
establish and tear down a connection between the terminal equipment and a 
software application. Data is transported between the terminal equipment and 
the software over the connection established over the DATA-CHL. 
A system with a single SPE has a single Network Control circuit pack. Thus, there 
is a single DATA-CON. A High or Critical Reliability system has two Network 
Control circuit packs, one in each of the two SPEs. Thus, there is a DATA-CON 
on the Network Control circuit pack that resides in the Active SPE control carrier 
and a DATA-CON on the Network Control circuit pack that resides in the Standby 
SPE control carrier. Refer to Chapter 6, "Reliability Systems: A Maintenance Aid", 
and the STBY-SPE (Standby SPE) Maintenance documentation for discussions of 
High and Critical Reliability systems.
From an external (user) point of view, the DATA-CON is not directly accessible 
via a system technician command; that is, there is no object command word that 
represents it. Instead, the DATA-CON is tested under the guise of the 
DATA-CHLs that it controls. The 
test data-module <ext> [short | long]
 
command tests the DATA-CON along with the DATA-CHL designated by <ext> 
but all Test Results are associated with the DATA-CHL Maintenance Name.
From an internal (system software) point of view, the DATA-CON uses the same 
set of tests as the DATA-CHLs. Therefore, the DATA-CON assumes the same 
Error Type and Aux Data values as the DATA-CHLs in the Hardware Error Log. It 
is also alarmed at the same Alarm Level (that is, MINOR, ON BOARD) in the 
Alarm Log. In both logs, the Maintenance Name is DATA-CON.
MO Name (in 
Alarm Log)
Alarm 
Level
Initial Command to Run
Full Name of MO
DATA-CON
MINOR
none
Network Control Driver