Lucent Technologies R5SI 用户手册

下载
页码 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-419
DAT-LINE (Data Line) 
10
Digital Loop Around Test (#171)
The Digital Loop Around Test checks the Data Line’s ability to transmit and 
receive data on the TDM Bus. Data is sent through Network Control Data 
Channel 3 (data channel port 3) over the TDM Bus, internally looped through the 
Data Line back onto the TDM Bus, and received again by Network Control Data 
Channel 3.
If data channel 3 is in use or not administered, this test aborts. This test may fail if 
Network Control Data Channel 3 is not functioning properly. If there are any 
DATA-CHL errors in the Error Log, refer to the DATA-BD (Network Control Circuit 
Pack) Maintenance documentation to clear them up first. This test passes 
regardless of any customer equipment that may be connected to the port, as 
long as the port is not in use by the equipment.
Table 10-117.
TEST #36 Audit Update Test 
Error 
Code
Test 
Result
Description/ Recommendation
1006
ABORT
The test did not run due to an already existing error on this port (Error Type 
769).
1. Refer to the procedure for Error Type 769. If Error Type 769 still occurs 
on this port, replace the circuit pack.
2000
ABORT
Response to the test request was not received within the allowable time 
period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
7
FAIL
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS
The hardware port state is consistent with the software state. User-reported 
troubles on this port should be investigated using other port tests, 
examining the ADU, external wiring, and customer equipment.
Continued on next page