Maintenance Object Repair Procedures
Page 10-453
DID-TRK (DID Trunk)
10
Loop Around and Conference Circuit Test (#33)
This test checks the reflective and non-reflective loop around and conference
capabilities of a DID port circuit. The test that uses 404-Hz, 1004-Hz, and
2804-Hz tones is an on-board test only. Each tone is separately transmitted to
and from the port (loop around within the port) and verified.
capabilities of a DID port circuit. The test that uses 404-Hz, 1004-Hz, and
2804-Hz tones is an on-board test only. Each tone is separately transmitted to
and from the port (loop around within the port) and verified.
This test may fail due to noise induced by adjacent electric power lines.
Customers having this problem should resolve it with their local power company.
To temporarily alleviate the alarm caused by the failure of this test, the test may
be disabled from trunk administration Test field. (This also disables the port
diagnostic test.
Customers having this problem should resolve it with their local power company.
To temporarily alleviate the alarm caused by the failure of this test, the test may
be disabled from trunk administration Test field. (This also disables the port
diagnostic test.
0
NO
BOARD
BOARD
The test could not relate the internal ID to the port (no
board).
board).
1. Check to ensure that the board translations are
correct. Translate the board, if necessary.
2. Issue the
busyout board
command.
3. Issue the
reset board
command.
4. Issue the
release busy board
command.
5. Issue the
test board
command. This should
re-establish the linkage between the internal ID and
the port.
the port.
Table 10-124.
TEST #6 NPE Crosstalk Test —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page