Lucent Technologies R5SI 用户手册
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-462
DID-TRK (DID Trunk)
10
Port Audit Update Test (#36)
This test sends updates of the DID port translation for all ports on the circuit pack
that have been translated. The update is non-disruptive and guards against
possible corruption of translation data contained on the circuit pack. No
response message is expected from the circuit pack once it receives translation
updates. The port translation data includes: wink or immediate start trunk, dial
tone or rotary dialing trunk, rotary dialing inter-digit timing, Network balance
R/RC, and disconnect timing.
that have been translated. The update is non-disruptive and guards against
possible corruption of translation data contained on the circuit pack. No
response message is expected from the circuit pack once it receives translation
updates. The port translation data includes: wink or immediate start trunk, dial
tone or rotary dialing trunk, rotary dialing inter-digit timing, Network balance
R/RC, and disconnect timing.
PASS
Current flow was detected for this port.
1. User-reported troubles on this port should be
investigated using other port tests and by examining
connections.
connections.
2. Refer problem to the CO.
0
NO
BOARD
BOARD
The test could not relate the internal ID to the port (no
board).
board).
1. Check to ensure that the board translations are
correct. Translate the board, if necessary.
2. Issue the
busyout board
command.
3. Issue the
reset board
command.
4. Issue the
release busy board
command.
5. Issue the
test board
command. This should
re-establish the linkage between the internal ID and
the port.
the port.
Table 10-126.
TEST #35 Port Diagnostic Test —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page