DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-462
DID-TRK (DID Trunk) 
10
Port Audit Update Test (#36)
This test sends updates of the DID port translation for all ports on the circuit pack 
that have been translated. The update is non-disruptive and guards against 
possible corruption of translation data contained on the circuit pack. No 
response message is expected from the circuit pack once it receives translation 
updates. The port translation data includes: wink or immediate start trunk, dial 
tone or rotary dialing trunk, rotary dialing inter-digit timing, Network balance 
R/RC, and disconnect timing.
PASS
Current flow was detected for this port.
1. User-reported troubles on this port should be 
investigated using other port tests and by examining 
connections.
2. Refer problem to the CO.
0
NO 
BOARD
The test could not relate the internal ID to the port (no 
board).
1. Check to ensure that the board translations are 
correct. Translate the board, if necessary.
2. Issue the 
busyout board
 command.
3. Issue the 
reset board
 command.
4. Issue the 
release busy board
 command.
5. Issue the 
test board
 command. This should 
re-establish the linkage between the internal ID and 
the port.
Table 10-126.
TEST #35 Port Diagnostic Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page