Lucent Technologies R5SI 用户手册

下载
页码 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-474
DIG-LINE (Digital Line) 
10
Hardware Error Log Entries and Test to Clear 
Values
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate test 
description and follow the recommended procedures.
2.
Major alarms on this MO may be downgraded to Warning alarms based on the value used in the set options 
command.
Digital Line Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm Level
On/Off
 Board
Test to Clear Value
0
1
0
Any
Any
Any
test port 
UUCSSpp
 sh r 1
1 (a)
40987
None
WARNING
OFF
1 (b)
1 to 20
None
WARNING
OFF
18 (c)
0
busyout port 
UUCSSpp
WARNING
OFF
rel port 
UUCSSpp
130 (d)
None
WARNING
ON
test port 
UUCSSpp
 sh
257 (e)
40971
None
513
0
Station (Digital) 
Audits Test (#17)
WARNING(o)
OFF
test port 
UUCSSpp
 sh r 6
767 (f)
40964
None
WARNING
OFF
769 (g)
40963 
40988
None
WARNING
OFF
1026(o)
NONE
WARNING
OFF
1281
Any
Station (Digital) 
Audits Test (#17)
WARNING
OFF
test port 
UUCSSpp
 sh r 4
1537 (h)
40968
None
WARNING
OFF
1793
Voice & Ctrl. Local 
Loop Test (#13)
MINOR/ 
WARNING
2
ON
test port 
UUCSSpp
 l r 3
2049
NPE Crosstalk Test 
(#9)
MINOR/ 
WARNING
3
ON
test port 
UUCSSpp
 l r 3
2304 (n)
None
2305 (i)
32770
None
2305 (h)
40967
None
3840 (k)
40965
None
3840 (l)
40989
None
3841 (m)
41029
None