Maintenance Object Repair Procedures 
Page 10-560
DS1-BD (DS1 Interface Circuit Pack) 
10
Major Alarm Inquiry Test (#142)
The Major alarm raised by a DS1 Interface circuit pack indicates that the average 
bit error rate on the DS1 facility is greater than 1/1000. The Major Alarm Inquiry 
Test is used to determine that the received DS1 bit error rate is greater than 
1/1000. When D4 framing mode is selected, the DS1 Interface circuit pack takes 
16 seconds to recognize and report a Major alarm and 16 seconds to recognize 
and report that a Major alarm condition is cleared. If ESF framing mode is 
selected, the DS1 Interface circuit pack takes 10 seconds to recognize and 
report a Major alarm and 10 seconds to recognize and report that a Major alarm 
condition is cleared.
When the DS1 Interface circuit pack detects a Major alarm, it will send a 
MAJOR-ALARM message to the maintenance software. After the maintenance 
software receives a MAJOR-ALARM message, the Major Alarm Inquiry Test is 
initiated to confirm the Major alarm on the DS1 Interface circuit pack. The Inquiry 
Test will be run every 10 minutes until the Major alarm is cleared. The 
maintenance software places all trunks on the circuit pack in the out-of-service 
state if the Major alarm persists for more than 20 minutes.
When the Major alarm is cleared, the maintenance software restores all trunks on 
the circuit pack to their previous service state before a Major alarm occurs.
Table 10-154.
TEST #142 Major Alarm Inquiry Test 
Error 
Code
Test 
Result
Description/ Recommendation
ABORT
Internal system error
 2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page