Lucent Technologies R5SI 用户手册

下载
页码 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-675
EXP-INTF (Expansion Interface Circuit Pack) 
10
Expansion Interface Local Loop Around Test 
(#240)
This test is similar to the Lightwave Transceiver Loop Around Test described in 
Test #242. A test tone from TDM Bus A is received by the Expansion Interface 
circuit pack under test, but is not transmitted out to the lightwave transceiver 
before being looped back onto TDM Bus A again. The test is then repeated using 
TDM Bus B. Thus, this loop back test is performed on each TDM Bus on the 
network containing the Expansion Interface circuit pack to verify that the 
Expansion Interface circuit pack is able to loop back data on each TDM Bus. 
Since this loop back is internal to the circuit pack, this test does not interfere with 
the normal fiber data stream.
0
NO 
BOARD
No board was detected by the test.
1. Check the error log for wrong board (error 125) or no board 
(error 131). Resolve either of these issues, if applicable.
2. Check that the board is properly translated and inserted. If so, 
check for hyperactivity (error 1538). If hyperactive, use the 
reset board PCSS 
command.
3. Run the test again. If it fails, the ID chip on board may be bad. 
Replace the board and retest.
Table 10-193.
TEST #240 EI Local Loop Around Test 
Error 
Code
Test 
Result
Description/Recommendation
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page
Table 10-192.
TEST #238 EI Fiber Out-of-Frame Query Test  — 
Continued
Error 
Code
Test 
Result
Description/Recommendation
Continued on next page