DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-679
EXP-INTF (Expansion Interface Circuit Pack) 
10
Expansion Interface 2-Way Transmission Test 
(#241)
This test is a basic connectivity test between the two cabinets. The test first 
sends a test tone from the cabinet of the Expansion Interface circuit pack under 
test through the opposite Expansion Interface circuit pack to a Tone Detector in 
the opposite cabinet. The connections are then reversed and the tone is passed 
in the opposite direction. This test should be run once from each Expansion 
Interface circuit pack on the fiber.
0
NO 
BOARD
No board was detected by the test.
1. Check the error log for wrong board (error 125) or no board (error 
131). Resolve either of these issues, if applicable.
2. Check that the board is properly translated and inserted. If so, 
check for hyperactivity (error 1538). If hyperactive, use the 
reset 
board PCSS 
command.
3. Run the test again. If it fails, the ID chip on board may be bad. 
Replace the board and retest.
Table 10-194.
TEST #241 Expansion Interface 2-Way Transmission Test
Error 
Code
Test 
Result
Description/Recommendation
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1002
ABORT
The system could not allocate time slots for the test. The system may 
be under heavy traffic conditions or it may have time slots 
out-of-service due to TDM-BUS errors. Refer to TDM-BUS (TDM Bus) 
Maintenance documentation to diagnose any active TDM-BUS 
errors.
1. If the system has no TDM-BUS errors and is not handling heavy 
traffic, repeat test at 1-minute intervals a maximum of 5 times.
Continued on next page
Table 10-193.
TEST #240 EI Local Loop Around Test  — 
Continued
Error 
Code
Test 
Result
Description/Recommendation
Continued on next page