DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-709
EXT-DEV ADMIN? N (External Device Alarm) 
10
Hardware Error Log Entries and Test to Clear 
Values
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when 
inspecting errors in the system. By clearing error codes associated with the 
Battery & Battery Charger Query Test,
 you may also clear errors generated from 
other tests in the testing sequence.
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
2.
One port generates a MAJOR alarm; the other port generates a MINOR alarm.
Table 10-200.
Hardware Error Log Entries and Test to Clear Values
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
test environment UU r2 
or 6
1 or 5
Any
External Device 
Alarm Test (#120)
MAJOR 
MINOR
2
OFF
test environment UU r 2 
or 6
Multicarrier Cabinet Tests
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
Battery & Battery Charger Query Test (#5) (a)
X
X
ND
AC Power Query Test (#78) (b)
X
X
ND
OLS Query Test (Carrier E) (#127) (c)
X
X
ND
OLS Query Test (Carrier D) (#127) (c)
X
X
ND
OLS Query Test (Carrier A) (#127) (c)
X
X
ND
OLS Query Test (Carrier B) (#127) (c)
X
X
ND
OLS Query Test (Carrier C) (#127) (c)
X
X
ND
Emergency Transfer Query Test (#124) (d)
X
X
ND
Cabinet Sensors Query Test (#122) (e)
X
X
ND
External Device Alarm Test (MAJOR port) (#120)
X
X
ND
Continued on next page